Sierra Monitor Corporation IZS31 Air Cleaner User Manual


 
1
8
8. LED display
POWER LED ・・・ The power supply input and the connection of the sensors are displayed.
LED name Functions
MAIN Lights up when the power supply is applied. (Green)
(Flashes when wrong power supply is applied.
POWER
SNSR Lights up when the auto balance sensor is connected.(Green)
ION LED ・・・ The discharged ion polarity and ion balance are displayed.
The ion balance state can be identified with the LED display.
Ion balance OK LED
Below +/-30V
Lighet up.(or flashes)
+/-30V or more Goes out
LED [OK] flashes when the ion balance nears the limit of the adjustment of the ion balance and indicates that
it is time for maintenance of the electrode needle.
ALARM LED ・・・ Failure of the ionizer will be indicated.
LED name Functions
HV Lights up when overcurrent is applied to the electrode
needle.Red
SNSR
Lights up when the auto balance sensor doesn’t work properly.Red
ALARM
NDL
CHECK
Lights up when dirt on the electrode needle is detected. Red
Flashes when the dirt is being detected.
LED name Function
Lights on when plus ions are generated.(Orange)
OK
With auto balance sensorCondition of the ion balance Green
W/o auto balance sensor Goes out
ION
Lights on when minus ions are generated.(Blue)