Skuttle Indoor Air Quality Products 60-2, F60-2 Humidifier User Manual


 
PROBLEM EVIDENCE SOLUTIONS(S)
Low Humidity Low water level (less than • See Plumbing and Setting Water
2-3/8" deep) Level, steps 4 & 5
No water in reservoir • Turn water on at saddle valve
•Turn off water main and check
for possible obstruction in saddle
valve or float valve
Humidifier heater is not • Make sure the humidifier is
operating plugged in
Set the humidistat higher
Check for blown circuit breaker
Check all external wiring connec-
tions
Check for low water level
Check the humidistat switch for
continuity
Call a professional HVAC con-
tractor
Rapid air changes (drafts) • Keep doors and windows closed
(cold, dry air is an added load
on the humidifier)
Close fireplace damper when
not in use
Keep exhaust fan running time
to a minimum
Seal around doors and windows
High Humidity Condensation on walls • Turn humidistat off
•Turn water to humidifier off
until condensation is evaporated
Heavy condensation on • Turn humidistat down enough
windows to eliminate condensation (this
may be a temporary condition
caused by moisture from bathing,
mopping, cooking, etc.)
Humidifier Overflows High water level • Inspect valve seat for defects
Inspect valve nozzle for cracks
or erosion
Readjust water level (see
Plumbing and Setting Water
Level
Make sure humidifier is level
27
CONTRACTOR
Trouble Shooting
Table 1