10. Check the two compression fittings – one at the saddle valve, the
other at the float valve. Stop any leakage by tightening the fitting.
11. Connect the humidifier's overflow provision to a suitable waste drain.
•Astandard garden hose or a 3/8" N.P.T. male fitting (not supplied)
can be attached to the overflow fitting.
Provide support at many points along the hose to prevent kinks –
particularly near any heat source.
12. Turn the water to the humidifier on. The float valve should shut the
water off at 2-3/8".
13. Make sure the humidifier is plugged into a powered outlet.
14. Adjust the humidistat according to instructions provided with the
humidistat.
NOTE:
See “How To Maintain the Skuttle Steam Humidifier” (next