Skuttle Indoor Air Quality Products 60-2, F60-2 Humidifier User Manual


 
16
Option D: Internal Side Mount
Figure 4 - Internal Side Mount
Option D requires a transition to be made and usually needs duct rein-
forcement to hold the humidifier securely in place (see Figure 4).
DANGER: Wear safety glasses when cutting or drilling. Do not cut
into any air conditioning or electrical accessories during installation.
Electrocution is possible if you come in contact with a live electrical
wire; blindness can occur if Freon contacts your eyes.
To install:
1. Construct a transition and attach it to to the plenum.
2. Attach the humidifier mounting template to the location selected on
the side of the transition.
3. Use a 7/64" drill bit to drill eleven (11) holes, as indicated on the
template. Drill a hole in the center of the shaded area of the template
and remove the area between the solid bold line using tin snips.
CAUTION:
Follow the dotted line carefully.
4. Remove the template.
5. Attach the L-shaped bracket with six (6) holes to the top/front of the
humidifier, so that the vertical wall is toward the reservoir.