Skuttle Indoor Air Quality Products 60-2, F60-2 Humidifier User Manual


 
22
Plumbing and Setting the Water Level
NOTE: Use a copper tubing only to plumb this humidifier.
1. Select the nearest cold water pipe and install the saddle connector
and needle valve (provided) by following the instructions supplied
with the valve.
WARNING: Do not use any line connected to an air conditioner.
2. Lightly clean the tubing ends with fine sandpaper before making any
connections.
3. Uncoil the copper tubing and connect one end to the saddle valve.
Use the compression fittings found in the self-piercing saddle valve
parts bag.
Place the brass compression nut over the tubing, then slide the
brass ferrule over the tubing.
Fully insert the tubing into the saddle valve fitting and tighten the
compression nut. (Do not over-tighten; moderate tightness should
prevent leaking.)
Thoroughly flush the supply tubing after attaching it to the saddle
valve. This will clear the line of debris which could block water flow
at the float valve.
4. Prior to mounting, adjust the humidifier’s water level by following
these instructions:
Set the humidifier reservoir on a level surface.
Attach the water line and allow the unit to fill until the float valve
shuts off the incoming flow of water. (The water should be 2-3/8"
deep, plus or minus 1/8". If it is not, further adjustment will be
necessary.)