Dulcodes UV-Desinfektionsanlage
Operating
8 Operating
This section describes all operating options available to you when the S2Ca is in continuous
display mode (no P key symbol in the LCD display).
WARNING
For all metering pumps for metering inflammable media applies: Starting up and
emptying only supervised by a competent person.
NOTE
Open out the fold-out page following the title page fully! There you will find the overviews
“control elements and key functions” and “operating/settings diagram”.
Look at the overview “continuous displays”. This page shows you which displays are
available in which operating mode, and which values are directly alterable in the
corresponding continuous displays.
8.1 Manual operation
Set stroke length Stroke length is continually adjustable within a range of 0-100 %. The recommended stroke
length range, which will practically guarantee technical reproducibility, is 30-100 % (SEK type:
50-100 %).
NOTE
At low stroking rates (less than 1/3 maximum stroking rate) the controller switches to
digital stroking mode. This ensures adequate cooling of the motor at low stroking rates.
The following operating options are available via the different keys (see also figure on the next
page):
Stop/Start S2Ca To stop S2Ca: press STOP/START key.
To start S2Ca: press STOP/START key.
Start batch Press the P key briefly in batch operating mode.
Load factory settings Press the P key for 15 s to load factory calibration settings!
Current settings will be deleted.
Change to settings mode When you press the P key for 2 s in any continuous display the S2Ca will change to settings
mode (see section 7).
If CODE 1 is set, the code must be entered after pressing the P key.
Check adjustable values Each time you press the i key you will see a different continuous display. The number of
continuous displays depends upon the identity code, the selected operating mode and the
connected accessories.
Change directly
alterable values To change a value (see below) directly in the corresponding continuous display, press one of
the arrow keys until set appears in the LCD display. The delay has been programmed in to
prevent inadvertent changing of values.
If CODE 2 has been set, this code must be entered after pressing the arrow key.
Directly alterable values are as follows:
Stroke rate In manual, contact and batch operating modes:
The stroke rate can be altered in the stroke rate display.
Feed rate In manual operating mode
The feed rate can be altered in the feed rate display.
Factor The factor is the number of strokes activated by an external pulse or a press of the P key (in
batch mode only).
In Batch operating mode:
You can alter the factor from the remaining strokes display.
The S2Ca returns to the original continuous display a few seconds after the factor has been
reset.
Display program version Press the P key for 10 seconds to display the program version.
Example: V1052 + X1010.
In the case of LOAD3 release the key immediately!