Sigma S2Ca Heat Pump User Manual


 
Page 48
ProMinent
®
Dulcodes UV-Desinfektionsanlage
Settings
In the contact - identity code: external with external pulse control you can enter the number
of pulses after which a stroke should be carried out. Contact - identity code: external with
external pulse control is intended for small dosing quantities.
P
PP
P
Continuous
display
Set
Set
Mem
Contact
Set
Mem
Contact
The number of strokes per pulse depends upon the factor, which you can enter. This allows
you to vary to a certain extent the input pulses by a factor of 1.01 to 99.99 and/or reduce by a
factor of 0.01 to 0.99:
Number of strokes activated = factor x number of input pulses
Examples Factor Pulse (sequential) Stroke number (sequential)
Increase 11 1
21 2
25 1 25
99.99 1 99.99
1.50 1 1.5 (1 / 2)
1.25 1 1.25 (1 / 1 / 1 / 2)
Reduction 11 1
0.50 2 1
0.10 10 1
0.01 100 1
0.25 4 1
0.40 2.5 (3 / 2) (1 / 1)
0.75 1.33 (2 / 1 / 1) (1 / 1 / 1)
Explanation of increase At a factor of 1 For every 1 pulse, 1 stroke is activated
At a factor of 2 For every 1 pulse, 2 strokes are activated
At a factor of 25 For every 1 pulse, 25 strokes are activated
Explanation of decrease At a factor of 1 After 1 pulse, 1 stroke is activated
At a factor of 0.5 After 2 pulses, 1 stroke is activated
At a factor of 0.1 After 10 pulses, 1 stroke is activated
At a factor of 0.75 After 2 pulses, 1 stroke is activated,
then after 1 pulse, 1 stroke is activated,
then after 2 pulses, 1 stroke is activated etc.