Sigma S2Ca Heat Pump User Manual


 
Dulcodes UV-Desinfektionsanlage
Page 33
ProMinent
®
Features of the S2Ca metering pumps
5 Features of the S2Ca metering pumps
5.1 Function description, motors
The pump has an integrated electronic overload cut-out in all versions. This responds as soon as
the maximum admissible power consumption is reached and stops the motor.
̈ If the motor stops due to a system overload the electronic controller detects the fault and
transmits a message which is displayed on the display panel and at the pump.
̈ The fault signal can be cancelled by pressing the P key, altering the level for a brief period at
the pause input (switch function) or by reconnecting the pump to the mains.
IMPORTANT
If the motor has been switched off via the electronic overload cut-out, check that the pump
is not continuously overloaded.
NOTE
The motor is supplied pre-wired.
The performance data in 3.1.1 are measured with the S2Ba (base model with 3-phase
motor). If the S2Ba has been fitted with a 1-phase motor there may be up to 5 % speed
reduction due to the different motor characteristic curve, i.e. corresponding 5 % reduced
feed rate.
The controller changes over to digital stroking mode at low stroke frequencies! This takes
place at stroke frequencies below 1/3 of the maximum stroke frequency. This function is
designed to ensure sufficient cooling of the motor and low stroke frequencies.
Type: 100 230 V ± 10 %, 50/60 Hz
at 100 V at 230 V
nominal output 250 W 250 W
nominal current 3.2 A 2.0 A
peak current (in operation)* 10 A 5.5 A
making peak current 12 A 24 A
fuse, internal** 4.0 AT (1.5kA) 4.0 AT (1.5kA)
* internal switching
** Only genuine ProMinent fuses, item no. 732414, may be used!
5.2 Function description, controller
Operating modes Operating modes are selected using the MODE menu (depending upon identity code, some
operating modes may be absent).
“Analogue” operating mode: (Identity code, control variant: analogue)
The stroke rate is controlled via an analogue electrical signal via the external control terminal.
Signal processing is pre-selected at the controller.
“Manual” operating mode:
The stroke rate is controlled manually via the controller.
“Contact” operating mode:
This operating mode offers the opportunity to make fine adjustments with small increase/
decrease factors. Dosing can be activated by a pulse via the external control terminal or by a
semiconductor element. With the pulse control option it is possible to pre-set a feed quantity
(batch) or number of strokes (factor 0.01 to 99.99) via the control unit.
“Batch” operating function:
This operating mode offers the option of working with larger transfer factors (up to 65535).
Metering can be triggered by pressing the P key or a pulse from the external control terminal
via a contact or semiconductor element. A batching quantity or number of strokes can be pre-
selected via the control unit.