Dulcodes UV-Desinfektionsanlage
Page 25
ProMinent
®
3Technical data
3.1 Technical data Sigma/ 2
3.1.1 Capacity data
Technical data S2Ba at 50 Hz operation
Feed rate at Max. Suction Admissible Connection Shipping
maximum stroke lift priming suction / weight
back pressure rate pressure discharge
suction side side
Pump type Sigma/ bar l/h ml/stroke strokes/min. m Ws bar G - DN kg
12050 PVT 10 50 11.4 73 7 3 1"-15 15
12050 SST 12 48 11.4 73 7 3 1"-15 20
16050 SST 16 48 11.4 73 7 3 1"-15 20
12090 PVT 10 90 11.4 132 7 3 1"-15 15
12090 SST 12 86 11.4 132 7 3 1"-15 20
16090 SST 16 86 11.4 132 7 3 1"-15 20
12130 PVT 10 130 10.9 198 7 3 1"-15 15
12130 SST 12 125 10.9 198 7 3 1"-15 20
16130 SST 16 125 10.9 198 7 3 1"-15 20
07120 PVT 7 120 27.4 73 5 1 20* 16
07120 SST 7 120 27.4 73 5 1 20* 24
07220 PVT 7 220 27.7 132 5 1 20* 16
07220 SST 7 220 27.7 132 5 1 20* 24
04350 PVT 4 350 29.4 198 5 1 20* 16
04350 SST 4 350 29.4 198 5 1 20* 24
All performance data applies to water at 20 °C.
The suction lift applies when the suction line and liquid end are full and correctly installed.
* Sigma types 07120, 07220 and 04350, the valves used in the liquid end are DN 25 (G1
1
/2). Since DN 20 is usually adequate for
this tubing (see Technical Data, connection-suction/discharge side) the connector parts to be ordered by Identcode (e.g.
washers) have already been reduced to DN 20, i.e. tubing and accessories can be DN 20.
Technical data
Technical data S2Ba at 60 Hz operation
Feed rate at Max. Suction Admissible Connection Shipping
maximum stroke lift priming suction / weight
back pressure rate pressure discharge
suction side side
Pump type Sigma/ bar psi I/h/gph strokes/min. m Ws bar G - DN kg
12050 PVT 10 145 60/ 15.9 87 7 3 1"-15 15
12050 SST 12 174 57/ 15.2 87 7 3 1"-15 20
16050 SST 16 232 57/ 15.2 87 7 3 1"-15 20
12090 PVT 10 145 108/ 28.5 156 7 3 1"-15 15
12090 SST 12 174 103/ 27 156 7 3 1"-15 20
16090 SST 16 232 103/ 27 156 7 3 1"-15 20
12130 PVT 10 145 156/ 41 232 7 3 1"-15 15
12130 SST 12 174 150/ 39.6 232 7 3 1"-15 20
16130 SST 16 232 150/ 39.6 232 7 3 1"-15 20
07120 PVT 7 100 144/ 38 87 5 1 20* 16
07120 SST 7 100 144/ 38 87 5 1 20* 24
07220 PVT 7 100 264/ 69.7 156 5 1 20* 16
07220 SST 7 100 264/ 69.7 156 5 1 20* 24
04350 PVT 4 58 420/ 111 232 5 1 20* 16
04350 SST 4 58 420/ 111 232 5 1 20* 24
All performance data applies to water at 20 °C.
The suction lift applies when the suction line and liquid end are full and correctly installed.
* Sigma types 07120, 07220 and 04350, the valves used in the liquid end are DN 25 (G1
1
/2). Since DN 20 is usually adequate for
this tubing (see Technical Data, connection-suction/discharge side) the connector parts to be ordered by Identcode (e.g.
washers) have already been reduced to DN 20, i.e. tubing and accessories can be DN 20.