Sharp CV-P09FR Air Conditioner User Manual


 
The exhaust hose must be installed or removed in accordance with the usage mode.
Mode Exhaust hose
COOL, FAN, VENTILATION Install
DEHUMIDIFICATION Remove
Installation of the exhaust hose
1
Attach the insect guard net to the ex-
haust adapter.
Push the insect guard net firmly to ensure
that four projections on the exhaust adapter
fit into the four holes on it.
2
Attach the Exhaust adapter to the
exhaust hose.
Extend one end of the exhaust hose and
insert it into the Exhaust adapter, and turn
it (approx. three times) until it stops.
Make sure they are securely attached
afterwards.
3
Attach the exhaust hose adapter to
the unit.
Insert the two projections on the exhaust
hose adapter into the two holes on the unit,
and firmly attach them to each other.
4
Lead the exhaust hose outdoors
Suction disk may be used to keep window
or door closed.
Exhaust hose
Exhaust adapter
Projection
Extend
Hole
E-8
The exhaust hose should be as short as possible for operational efficiency;
however, it must not be twisted or bent.
Unacceptable
Acceptable
Acceptable
INSTALLATION AND REMOVAL OF EXHAUST HOSE
Projection
Removal of the exhaust hose
1
Remove the exhaust hose adapter from
the unit.
Lift up and remove the exhaust hose adapter
from the unit by pushing down on the two
projections.
Insent guard net
Suction disk
Hole
Projection