Sharp CV-P09FR Air Conditioner User Manual


 
ENGLISH
DRAINAGE
Prepare for drainage and drain out water within the unit in the following cases.
If the unit stops operating and the TIMER (
), OPERATION ( ) and TURBO COOL ( )
lamps are blinking. (This indicates that the water tank inside the unit is full.)
1
Make sure to turn the unit off.
2
Turn the drainage nozzle to the OPEN
position.
3
Pull the stopcock out from the drainage
nozzle.
When the stopcock is removed, a small amount of
water may be discharged from the drainage nozzle.
4
Insert the hose clamp into a standard com-
mercially available hose (12.7 mm inner di-
ameter, 16.7 mm outer diameter).
5
Attach the hose to the drainage nozzle, and
secure it with the hose clamp.
Prepare for draining, as drain water will come out
through the hose during operation.
6
Press the AUX. button on the unit twice.
The water will drain out through the drainage hose.
Mximum amount of water that may be drained out
is approximately 2 liters.
The OPERATION, TIMER and TURBO COOL
lamps will be blinking.
7
When drainage water stops running out from the hose, turn the unit off by
pressing AUX. button.
This would take about one minute.
8
Remove the hose from the drainage nozzle, and replace the stopcock.
Keep the hose clamp in case of re-used.
9
Turn the drainage nozzle to the CLOSE position.
Whenever the unit is moved (to provent water within the unit from spilling).
When the unit is not used for a long time.
1
Carry out the above procedures from 1 to 5.
2
Press the AUX. button on the unit.
The water will drain out through the drainage hose.
Mximum amount of water that may be drained out is approximately 2 liters.
The OPERATION lamps will light.
3
When drainage water stops running out from the hose, turn the unit off by
pressing AUX. button.
This would take about one minute.
4
Remove the hose from the drainage nozzle, and replace the stopcock.
Keep the hose clamp in case of re-used.
5
Turn the drainage nozzle to the CLOSE position.
6
Remove the stopcock from the drainpipe nozzle, and completely drain any
water within the unit.
Always prepare a receptacle to collect the water
before draining. Mximum amount of water that may
be drained out is approximately 0.2 liters.
7
Replace the stopcock to the drainpipe nozzle.
E-17
Stopcock
Drainpipe nozzle
Drainage
nozzle
Stopcock
“OPEN position”
Hose clamp
Hose