Latching Authorization
Placing jumpers across the 4
th
and 5
th
set of pins (1,2 LATCH
or 3,4,5 LATCH) determines
which relay (if any) each User
Group is authorized to
manually latch.
How to Latch
When a valid code is
entered on the keypad
followed by “7”, the Latch
Authorization relay for that particular User Group will
energize and remain energized until a valid code followed
by “7” is entered again
.
Example:
1. Placing a jumper across the 1
st
and 2
nd
pins of the “1, 2
LATCH” option allows User 1 and User 2 to Latch
Relay #2.
2. Leaving a jumper off the “3,4,5 LATCH” option
prevents User 3, User 4 and User 5 from latching either
relay.
Note: Because the Master Code is primarily used to
program User codes, the Master Code does not have
Latching Authorization.
CCTV/Doorbell Setup
Placing jumpers across the 6
th
or
7
th
set of pins (CCTV or
DOORBELL) determines which
relay (if any) will be used to
activate a CCTV or Doorbell.
CCTV Operation: If either
relay is configured to
activate a CCTV, any key
press on the Keypad triggers
a 10 second output.
Doorbell Operation: If either relay is configured to activate
a doorbell, pressing ∗ at the Keypad triggers a 1 second
output. (Doorbell only functions with 12-Pad 3x4 or
Thinline 2x6)
Ex: Latching Authorization
Ex: CCTV Setup
13
2
nd
Door Operation
The KE-265 has been
designed to provide 2 door
operation with one or more
Keypads. With this
configuration, certain codes
will activate Relay #1 and
certain codes will activate
Relay #2. (Connect Relay #2
to the 2
nd
Locking Device)
Example:
1. Placing a jumper across the 2
nd
and 3
rd
pins of the
“MASTER UNLOCK” option allows the master code to
activate (unlock) Relay #1.
2. Placing a jumper across the 2
nd
and 3
rd
pins of the “1,2
UNLOCK” option allows User Code 1 and User Code 2
to activate (unlock) Relay #1.
3. Placing a jumper across the 1
st
and 2
nd
pins of the
“3,4,5 UNLOCK” option allows User Code 3, User
Code 4 and User Code 5 to activate (unlock) Relay #2
4. In this example, User Code 1 and User Code 2 have
also been given Latching Authorization for Relay #1.
Note: In order for 2 Door configuration to operate correctly,
be sure to
remove any jumpers across the CCTV option and
the
Doorbell option.
Tamper Alarm Lockout
A person attempting to gain entry by guessing the code and
pushing 25 wrong digits will cause the KE-265 to go into
tamper alarm mode. The Keypad will beep constantly for 30
seconds during which time the door will remain locked and no
keypad functions can be performed.
Ex: 2