SECTION 5 SERVICE TECH INFORMATION
5C .. WATER FLOW THROUGH THE SOFTENER VALVE
SERVICE CYCLE
VALVE OUTLET !_
(SOFT WA_ _[
[.'lRESIN",
I! BED?
INLET
WATER)
TOP
DISTRIBUTOR
RESIN
\TANK
I RESIN _._"
' _BED, _'_
_ BOTTOM
DISTRIBUTOR
POSITION
SWITCH
Hard water enters the valve inlet port. Internal valve porting routes the water
down and out the top distributor, into the resin tank. Hard water is softened
as it passes through the resin bed, then enters the bottom distributor. Soft
water flows back into the valve and out the valve outlet, to the house soft
water pipes.
FILL CYCLE
POSITION
SWITCH
VENTURI
VALVE CAM
ROTOR & DISC
FILL FLOW
PLUG VALVE INLET
FILL WATER (HARD WATER)
(SOFT) _OS,T,O.
VALVE OUTLET" SW,TCH
(SOFT WATER
To begin a regeneration, the electroic timer energizes lhe circuit to lhe valve
motor. The valve motor rotates the rotor and disc and the valve cam until the
position switch lever drops, to open the motor circuit and position the valve in
FILL. As the rotor and disc rotates, lhe port opens for SOFT water fill lhrough the
venmri. Fill flow continues to the brine valve, and into the salt storage tank. Soft
water is still available to the house lines.
_g