Sears 625.34854 Water System User Manual


 
SECTION 4 OTHER THINGS TO KNOW
4A. DIMENSIONS/SPECIFICATIONS
BYPASS VALVES
SINGLE-PLASTIC
PULL STEM
OUTWARD
FOR
SERVICE
Push
Inward
For
j Bypass
SINGLE-BRASS
For SH
Bypass I INWARD
I FOR
ISERV_CE
3-VALVE
SERVICE
Close Bypass Valve
Open Inlet & Outlet Valves
BYPASS
Open Bypass Valve
Close Inlet & Outlet Valves
Bypass
Valve
Inlet
Valve
A
F
/ \
/ \
I
B_
/
C
E
INCHES CM
A Salt Tank Height 40-1/4 102.2
B Resin Tank Diameter (nominal) 9 22.7
C Resin Tank Height (nominal) 40 101.6
D Inlet-Outlet Height 41-1/2 105.4
E Overall Height 46 116.8
F1 Length 19-1/2 49.5
F2 Width 16-1/2 41.9
- Distance between inlet-outlet 3-3/8 8.6
center lines
MODEL NO. 625.3485400 AND 625.3485500 TIMER AR CODE AR31
NOTE: Please see the rating decal for water softener operating capacity, salt usage and service flow
rate/pressure loss performance specifications. Performance specifications are validated by the Water
Quality Association (WQA). The rating decal is located on the rim, under the salt hole cover (see page
28).
WATER SUPPLY TO WATER SOFTENER
MINIMUM WATER SYSTEM FLOW (gpm) 3
MINIMUM-MAXIMUM WATER PRESSU RE (psi) 20-120
MAXIMUM WATER TEMPERATURE (°F) 120
MAXIMUM WATER HARDNESS (gpg) 110
MAXMUM 'CLEAR WATER"IRON (ppm) 8
SALT FOR WATER SOFTENER
TYPE OF SALT NEEDED Nugget/Pellet
ALTERNATE TYPE OF SALT Pure, evaporated, compacted
water softener salt
STORAGE CAPACITY (pounds) 200
OTHERS
TYPE OF ION EXCHANGE MATERIAL (resin) High Capacity
AMOUNT OF RESIN (cu,ft.) 1,0
REGENERATION (RECHARGE) CYCLE TIME (min,)
FILL 2.7-10.3
BRINING/BRINE RINSE 97-106
BACKWASH 7
FAST RINSE 3
TOTAL REGENERATION TIME 109,7-126,3
gpm : gallons per minute
gpg : grains per gallon
psi = pounds per square inch
ppm = parts per million
19