Sea Breeze Mini-Split Heat Pump Heat Pump User Manual


 
10
INDOOR UNIT INSTALLATION (Cont)
PREPARE REFRIGERATION LINES
Refrigeration lines and wiring can be routed from the indoor unit several different ways using the
cut-out access pieces on the back of the unit.
Bend the refrigeration lines carefully to the position needed to align with the drilled piping hole.
HANG INDOOR UNIT
Bundle the refrigeration lines, drainage hose, and wiring conduit attached to
the indoor unit and wrap them securely for enough length to extend through
the piping hole to the exterior of the building.
Note: leave remainder unwrapped to allow for remaining step in installation
of the outdoor unit and connecting the indoor unit to the outdoor unit.
Carefully push bundled lines through the piping hole.
Hang the unit on the wall by hooking the mounting slots of the unit over the
upper tabs of the rear panel.
Check to make sure the: unit is properly secured - it should feel firmly
attached to the wall, and you should not be able to slide it to the right or left.