2-2-2. Outdoor Unit
Outdoor Unit SAP–CRV93EH
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Compressor
Type DC Rotary (Hermetic)
Compressor model / Nominal output G4C090LU1ER / 600W
Compressor oil … Amount cc FV50S … 320
Coil resistance (Ambient temp. 20°C) U – V: 0.81
V – W: 0.81
W – U: 0.81
Safety devices
CT (Peak current cut-off control) YES
Compressor discharge temp. control YES
Operation cut-off control in abnormal ambient temp.
Run capacitor µF
VAC
Crankcase heater
Fan & Fan Motor
Type … Fan / Fan motor Propeller / AC motor
Q’ty … Dia. mm 1 … 370
Fan motor model … Q’ty IB-976-501 … 1
No. of poles … Rough measure rpm (Cool / Heat) 6 … 700 / 700
Nominal output W 20
Coil resistance (Ambient temp. 20°C) WHT BRN: 213
RED (PNK) WHT: 168
— :
Safety devices Type Thermal fuse
Operating temp. Open °C 150
Close °C
Run capacitor on control PCB (A) µF 2.0
VAC 440
Heat Exchanger Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.4
Face area m
2
0.288
External Finish Acrylic baked-on enamel finish
Control PCB (A) / Control PCB (B)
Part No. CB-CRV93EH (POW-CRV93GJH)
Controls Microprocessor
Control circuit fuse 250V, 20A