Sanyo SAP-KRV123EH Air Conditioner User Manual


 
8
Indoor Unit SAP–KRV123EH
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Control PCB
Part No. CB-KRV123EH (POW-KRV93GJH)
Controls Microprocessor
Control circuit fuse 250V 3.15A
Flap Motor and Louver Motor
Type Stepping motor
Model MP24Z3-12V
Rating DC 12V
Coil resistance (Ambient temp. 25°C) Each pair of terminals: 400 ± 7%
Heat Exchanger Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.3
Face area m
2
0.188
Fan & Fan Motor
Type Fan / Fan motor Cross-flow / AC motor
Q’ty … Dia. and lengthmm1 … D92 / L634
Fan motor model … Q’ty IBH-884-066 … 1
No. of poles … Rough measure rpm (Cool / Heat) 4 … 1,250 / 1,250
Nominal output W 30
Coil resistance (Ambient temp. 20°C) BRN WHT: 234
PNK (RED) WHT: 209
— :
Safety devices Type Thermal fuse
Operating temp. Open °C 130
Close
Run capacitor µF 1.2
VAC 440
Remote Control Unit RCS-3HVPSS4E