Sanyo SAP-KRV123EH Air Conditioner User Manual


 
19
5-3. Operating Frequency Charts
0
1
2
3
4
5
0 1020304050607080
Operating Freqency (Hz)
Cooling Capacity (kW)
54
Min.
Center
Max.
0
200
400
600
800
1000
1200
0 1020304050607080
Operating Freqency (Hz)
Power Input (W)
54
Min.
Center
Max.
755
2.65
Indoor Unit SAP–KRV93EH
Outdoor Unit SAP–CRV93EH
230V Single-phase 50Hz
NOTE
1) Rating conditions in cooling are:
Indoor: 27°C D.B. / 19°C W.B.
Outdoor: 35°C D.B. / 24°C W.B.
2) Fan speed: High
Cooling