Sanyo KH2672R / CH2672R Air Conditioner User Manual


 
1
2
3
4
5
6
I-57
SM831148
1. Specifications
1-3 Other Component Specifications
(A) Indoor Unit
MODEL No. KH2672R
Power Transformer ATR IIK244D R
Rated Primary AC 230 V, 60 Hz
Secondary BRN - BRN : 11 V / 1.25 A, RED - RED : 14 V / 0.45 A
Capacity
Coil resistance
WHT - WHT : 78.5 , RED - RED : 1.95
(Ambient temprature 77 °F) BRN - BRN : 0.42 , ORG - ORG : 6.11
Thermistor cut off temperature °F 277
Thermistor (Coil sensor) PBC - 41E - S4
Coil resistance k 14 °F : 23.7 , 59 °F : 8.0
23 °F : 18.8 , 68 °F : 6.5
32 °F : 15.0 , 86 °F : 4.4
41 °F : 12.1 , 104 °F : 3.1
50 °F : 9.7 , 113 °F : 2.6
Thermistor (Room or coil sensor) KTEC - 35 - S6
Coil resistance k 32 °F : 16.5 , 104 °F : 2.7
41 °F : 12.8 , 113 °F : 2.2
50 °F : 10.0 , 122 °F : 1.8
68 °F : 6.3 , 131 °F : 1.5
86 °F : 4.0 ,
DATA SUBJECT TO CHANGE WITHOUT NOTICE