SM831148
1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No. XH4272R
Source 230 - 208 VAC / 1 phase / 60 Hz
Remote controller (Option) Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y CR - TH2672
Control circuit fuse 250 VAC, 5 A
Fan (Number diameter) in. (mm) Turbo (117-7/16 (443))
Fan motor
Model SFG6X - 81A6P
Source 230 - 208 V / 1 phase / 60 Hz
No. of pole r.p.m. (230 V, High) rpm 6 506
Nominal output W 60
Coil resistance BRW - WHT : 75.1 , ORG - YEL : 27.4
(Ambient temperature 68 °F) WHT - VLT : 6.7 , VLT - PNK : 42.7
VLT - ORG : 20.6 , YEL - BLK : 58.0
Safety device
Operating temperature Open °F266± 14.4
Close °F 174.2 ± 27
Run capacitor VAC, µF 440 V , 6 µF
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows Fins per inch 2 14.9
Face area ft.
2
(m
2
) 8.20 (0.762)
Panel
Model No. PNR - XH3642
Auto louver motor MT8 - 3C
Auto louver motor Rated V, W, rpm 240 VAC , 3 W , 3 rpm
Coil resistance (Ambient temperature 77 °F) 16.430 ± 8 %