Sanyo KH2672R / CH2672R Air Conditioner User Manual


 
1
2
3
4
5
6
I-30
SM831148
1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No. TH2672R
Source 230 - 208 V / 1 phase / 60 Hz
Remote controller (Option) Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y CR - TH2672
Control circuit fuse 250 V, 5 A
Fan (Number diameter) in. (mm) Centrifugal (4 ... 5-1/8(130))
Fan motor
Model SR4X - 51A6P
Source 230 - 208 V / 1 phase / 60 Hz
No. of pole r.p.m. (230 V, High) rpm 1,179
Nominal output W 31
Coil resistance BRW - WHT : 111.0 , ORG - YEL : 16.7
(Ambient temperature 68 °F) WHT - VLT : 35.4 , BLK - PNK : 23.9
VLT - ORG : 13.4 , YEL - BLK : 136.6
Safety device
Operating temperature Open °F266± 14.4
Close °F 174.2 ± 27
Run capacitor VAC, µF 440 V , 1.5 µF
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows Fins per inch 3 14.9
Face area ft.
2
(m
2
) 1.81 (0.168)
Auto louver motor
Model No. MT8 - 3C
Auto louver motor Rated V, W, rpm 240 VAC , 3 W , 3 rpm
Coil resistance (Ambient temperature 77 °F) 16,430 ± 8 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE