1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No. XH2672R
Source 230 - 208 VAC / 1 phase / 60 Hz
Remote controller (Option) Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y CR - TH2672
Control circuit fuse 250 VAC, 5 A
Fan (Number … diameter) in. (mm) Turbo (1…17-7/16 (443))
Fan motor
Model SFG6X - 41D6P
Source 230 - 208 V / 1 phase / 60 Hz
No. of pole … r.p.m. (230 V, High) rpm 6 … 464
Nominal output W 40
Coil resistance BRW - WHT : 170.3 , ORG - YEL : 43.2
(Ambient temperature 68 °F) WHT - VLT : 18.1 , WHT - PNK : 83.5
VLT - ORG : 43.2 , YEL - BLK : 60.2
Safety device
Operating temperature Open °F 266 ± 14.4
Close °F 174.2 ± 27
Run capacitor VAC, µF 440 V , 4.5 µF
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows … Fins per inch 2 … 14.9
Face area ft.
2
(m
2
) 3.69 (0.343)
Panel
Model No. PNR - XH2442
Auto louver motor MT8 - 3C
Auto louver motor … Rated V, W, rpm 240 VAC , 3 W , 3 rpm
Coil resistance (Ambient temperature 77 °F) 16.430 ± 8 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE