Sanyo KH2672R / CH2672R Air Conditioner User Manual


 
1
2
3
4
5
6
I-19
SM831148
1. Specifications
1-1 Unit Specifications
Ceiling-Mounted Type
Indoor Unit THH2672R
Outdoor Unit CH2672R
POWER SOURCE
230 - 208 V / 1 Phase / 60 Hz
PERFORMANCE
Cooling Heating
Capacity * [minimum~muximum] BTU / h 24,400 [9,500~24,400] 30,800 [8,000~30,800]
(17˚F)** BTU / h 17,900
Moisture removal (High) Pints / h 7.7
Air circulation (H / M / L) 230 V CFM 550 / 490 / 460
External Static Pressure in. WG
S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 14.5 10.3
ELECTRICAL RATINGS
Voltage rating V 230 208 230 208
Available voltage range V VAC 187 - 253 VAC 187 - 253
Max. Running amperes* (Without Back-up Heater)
A 15.6 17.3 16.4 18.1
Power input W 2,880 2,880 3,000 3,000
(17˚F)** W 2,190 2,190
Back-up Heater kW 1.8 1.47
Maximum overcurrent protection (Indoor/Outdoor)
A 15 / 30
Controls Microprocessor
Low ambient control Built-in 0˚F
Fan speeds Indoor / Outdoor 3 and Automatic control / Variable
Optional Wired Remote Controller
Optional Wireless Remote Controller RCS-SH80UA. WL / RCS-BH80UA. WL
Air deflection (Horizontal / Vertical )
/ Automatic (Vertical )
Air filter Washable, long life (2,500 hr)
Drain pump (Drain connection) (20A , OD26mm)
Compressor Rotary(SANYO)
Operation sound
Indoor - Hi/Me/Lo
dB - A 39 / 37 / 33
Outdoor - Hi dB - A 49
Refrigerant control Electronic Expansion Valve (MOV)
REFRIGERANT TUBING
Limit of tubing length ft. (m) 165 (50)
Limit of tubing length at shipment ft. (m) 10~100 (3~30)
Limit of elevation difference ft. (m) Outdoor unit is higher than indoor unit : 100 (30)
between the two units ft. (m) Outdoor unit is lower than indoor unit : 50 (15)
Refrigerant tube Narrow tube in. (mm) 3 / 8 (6.35)
outer diameter Wide tube in. (mm) 5 / 8 (15.88)
Refrigerant amount at shipment lbs. (kg) 4.19 (1.9) - R410A
DIMENSIONS & WEIGHT
Indoor unit Outdoor unit
Unit dimensions Height in. (mm) 7-17/32 (190) 30- 23/32 (780)
Width in. (mm) 51-3/16 (1,300) 37 (940)
Depth in. (mm) 26-3/8 (670) 13- 3/8 (340)
Package dimensions Indoor unit Outdoor unit
Height in. (mm) 9-7/16 (240) 34- 31/32 (888)
Width in. (mm) 54-19/32 (1,387) 39- 31/32 (1,015)
Depth in. (mm) 31-1/16 (789) 16- 3/32 (409)
Net weight lbs. (kg) 64 (29) 128 (58)
Shipping weight lbs. (kg) 75 (34) 148 (67)
Shipping volume cu.ft. (m 3 ) 8.9 (0.253) 13.0 (0.369)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
FEATURES
MODEL No.
RCS-SH80UG / RCS-TM80BG
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB