Sankyo 11AR Home Security System User Manual


 
Unit 4
Installation
1616
4.4 Wiring
1.) Power Supply Connector Cable
Supplies DC +24V 400mA power supply to the MP940 module. The
connectors use a screw-mount terminal block BL3, 5/3F-AU (Weidmuller,
Inc.).
Pin# Signal Name Name
3 +24V +24VDC input
2 GND 0V
1 FG Frame ground
2.) Input Cable Preparing Procedure
Use a twisted pair with a wire size of AWG#24 to AWG#20 when connecting the
24VDC power supply and MP940 Module power supply connector.