Samsung AW0819 Air Conditioner User Manual


 
Installation
Before installation, be sure to check the installation area
for the air conditioner, and installation method of the drain hose.
Checkpoints prior to installation
Check the cabinet and front grille of the unit for any harmful defects
such as scratches.
1
Be sure to check the power supply.
- Refer to the specifications on the label attached to the unit.
2
2
Installation Conditions
Electrical Requirements
For personal safety:
This appliance must be properly grounded. See installation instructions.
Do not, under any circumstances, cut or remove the third grounding
prong from the power cord.
We recommend that you do not use an extension cord or an adapter
plug with this appliance.
Do not change the plug on the power cord of this appliance.
Follow national electrical codes or local codes and ordinances.
If the electric supply provided does not meet the above specifications,
call a licensed electrician.
Aluminum house wiring may pose special problems - consult a qualified
electrician.
This unit requires a separate circuit serving only this appliance.
Window Requirements
Standard double - hung window with actual opening width of 251/2" to 37".
The installation will need to be modified for windows other than
the standard double-hung type.
Clear vertical opening of 143/4" minimum from bottom of sash to sill.
Install the air conditioner in a window where there will be enough
clearance around the cabinet to allow ample circulation of air through
the unit.
115V
15 AMP circuit
"parallel" type
230V/208V
20 AMP circuit
"perpendicular" type
230V/208V
15 AMP circuit
"tandem" type
230V/208V
30 AMP circuit
"tandem" type
1
All supporting parts should be secured to firm wood,
masonry or metal.
14
3/4" min.
25
1/2" to 37"
E-12