Roper Stove Stove User Manual


 
but do not force it Forcing could damage the fitting and
tubing and cause leaking
Apply lrquld leakdetector to all connectlons 111 the supply Ilne.
manifold ,Ind oven to test for gas leaks
Do
not
use an open
flame 10 look for leaks
Bubbles will form where any gas IS
leaking rum off the matn gas supply before you try to stop
a !eak After all leaks are stopped, turn on the gas supply and
recheck all connections for leaks before llghtlng burners
All
leaks must be stopped before lighting any burners.
klt;jr e~t~ctrical and gas connections have been made, use a
1
E ‘drill t’lt !o droll holes In the cab/net front, through the holes
lr: it-10 3:‘z:i IrIm
Secure lh+d oven In the cabinet with ihe
?‘r!PLYc> rjro’Nfed
I .
‘-!+.I r OFF VA\-‘JE t IEHC IF
REZiJIF(ED BY LG( AL REGULATIOIIS
FqEGULATOR
MAKING L.P. GAS ADJUSTMENTS
A
If you are using L.P. (bottled) gas, all the
adjustments described below must be
made before you make any burner ad-
justments or use the oven.
To adjust your oven for use with L.P gas, follow the steps
below.
Step 1: Adjust Pressure Regulator
NOTE: The pressure regulator is set for natural gas. To
use L.P. gas, the regulator must be adjusted.
1 ocate the pressure regulator (see Fig. 5). Unscrew the cap
and remove the spring retainer, Fig 6 Turn the retainer over
and put it back into the cap so L P. is showing on the bottom
2nd of Ihe retainer
Replace the cap
CAP
rc
SPRING
RETAINER
PRESSUREREGULATOR Fig. 6
Slep 2: Adjust Burner Orifices
CAUTION: The following adjustment must be made
before turning on the burner. Failure to do so could
result in serious injury due lo high flames and toxic
fumes.
lJse a 1 2” open entl or adjustable wrench to turn all orifice
hoods in the L P dIrectIon, about l-l:2 turns or until snug
See nerl page
Do not overtighten or you may distort the
orifice hood and needle.
Pressure Test Information
The max~rnuni allowable pressure for the regulator IS 14”
W C
rhe minmurr pressure needed to check the regulator
setting 15 7” W C for natural gas or 11” W C lor L P gas
CAUTION: The range and its individual shut off valve
must be disconnected from the gas supply piping sys-
tem during any pressure testing of the gas supply
system at test pressures in excess of 112 psig (pounds
per square inch gauge).
The range must be isolated from the gas supply piping
system by closing its individual shut off valve during
any pressure testing of the gas supply system at test
pressures equal to or less than 112 psig.
GINS54
5