6.1 System Requirements
The CGTH-Series heater requires a grounded three-
prong electrical outlet to be installed within 18" (46
cm) of the rear surface of the heater's burner. It is rec-
ommended that the outlet for the heater be ceiling-
mounted and should be on a dedicated circuit. DO
NOT use an electrical extension cord to operate the
heater.
Heater Rating: 120V, 60 Hz, Single Phase, 1A
6.2 Grounding
The heater must be electrically grounded in accor-
dance with the following codes: United States: Refer
to National Electrical Code, ANSI/NFPA-70 - latest
revision. Wiring must conform to the most current
National Electrical Code and local ordinances. Can-
ada: Refer to Canadian Electrical Code, CSA C22.1
Part 1 - latest revision.
6.3 Important Notes
1. The CGTH-Series heater is controlled by a low volt-
age (24V AC) thermostat supplied with the heater.
The control transformer located inside the burner
supplies the necessary electrical power to operate
the thermostat. No other electrical power to the
thermostat is required.
2. The wire for connecting the thermostat to the
heater is not supplied. Refer to the installation
instructions supplied with the thermostat for cor-
rect wire sizing.
6.4 Thermostat Placement
For best results, locate the thermostat as follows:
• Mount the thermostat on an interior wall whenever
possible.
• Mount the thermostat approximately 60" (1524
mm) from the floor.
• Mount the thermostat so that it is shielded from
the heat that is radiated from the heater.
• Mount the thermostat over the thermostat tag that
is provided in the accessories bag. The thermo-
stat tag contains important safety information and
must be used.
6.5 Thermostat Installation
1. Connect thermostat wiring to the thermostat as
follows:
A. Attach one wire of the thermostat wires to the
"R" terminal on the rear of the thermostat;
attach the remaining wire to the "W" terminal
(See Figure 30).
B. Peel off backing of adhesive strips on the rear
surface of the thermostat tag and position the
tag against the wall; secure thermostat over
tag using two screws.
FIGURE 30: Thermostat Installation
Electrical Shock Hazard
Plug heater into grounded three-
prong ceiling receptacle.
Do not cut or remove the grounding
prong from this plug.
Do not use with an extension cord.
Failure to follow these instructions
can result in death or electrical
shock.
WARNING
°F 40 50 60 70
°C 5 10 15 20
OFF
● ● ● ● ●
R
W
FRONT
BACK
Fire Hazard
Some objects will catch fire or
explode when placed close to
heater.
Keep all flammable objects,
liquids and vapors the required
safe distances away from heater.
Keep children, clothing and
furniture away from the heater.
Failure to follow these
instructions will result in death,
injury or property damage.
WARNING
Printed in U.S.A./Imprimé aux Etats-Unis
This thermostat controls your overhead tube heater. Keep burner, control compartment and reflector clean. Read
your CGTH-Series Use and Care Manual (P/N 180101NA or GH80101NA) and follow all Safety Requirements which
include checking your heater monthly. Installation, Service and Annual Inspection must be done by a contractor
qualified in the installation and service of gas-fired heating equipment. Please call (716) 852-4400 (USA) or (905)
945-5403 (Canada) if you need a manual or have questions.
Ce thermostat commande votre radiateur. Gardez le module de contrôle et le reflécteur propres. Lisez le manuel
dutilisation et dentretien CGTH-Series (P/N 180101NA ou GH80101NA) et respectez tous les conseils de sécurité,
notamment le contrôle mensuel du radiateur. Linstallation, l'entretien et linspection annuelle doivent être effectués
par un agent agréé. Veuillez nous contactez au 716-852-4400 (USA) ou au 905-945-5403 (Canada) pour toutes
questions ou demandes de manuel.
MOUNT
THERMOSTAT
HERE
MONTER LE
THERMOSTAT ICI
ATTENTION
Risque d'incendie
Certains objets placés près du
radiateur peuvent s'enflammer ou
exploser.
Tenir tous les objets, iquides et
vapeurs inflammables à la
distance de sécurité requise du
radiateur.
Surveiffer les enfants. Gardes les
vêtements, les meubles loin de
l'appareil.
Le non-respect de ces consignes
peut causer dommage au matériel.
Required Safe Distances from Combustibles
Distances de Dégagement par Rapport aux Combustibles
Horizontal Mount
Montage Horizontal
45° Mount
Montage à 45°
24" Min. (61 cm)
A
A
D
D
E
E
A
A
F
F
Approx.
45 °
F
B
A
C
24" Min. (61 cm)
B
Rating Tag
Éttiquette de
Classement
by
CGTH-Series
®
NOTES:1 . Toutes les dimensions sont mesurées à partir du réflecteur.
2. Les chiffres noirs sont en pouces. Les chiffres oranges
sont en centimètres.
3.
Vous devrez connaître le numéro de votre modèle. Il se
trouve sur létiquette de classement. (Voir le dessin du
montage horizontal pour lemplacement de létiquette de
classement).
Model A B C D E F
CGTH-30 4 16 36 28 34 6
CGTH-40 4 18 48 30 34 6
CGTH-50 4 20 48 32 36 6
Modèle A B C D E F
CGTH-30 11 41 92 72 87 16
CGTH-401146 122 77 87 16
CGTH-50 11 51 122 82 92 16
©
www.rg-inc.com
P/N 91037903 Rev F
NOTES:1. All dimensions are from the reflector.
2. Black numerals are in inches. Orange numerals are in
centimeters.
3. Know your model number. Model number is found on the
rating tag. (See horizontal mount drawing for location of
rating tag).