20
Installation Checklist
BEFORE OPERATING THE WATER HEATER:
1. Check the gas line for leaks.
a. Use a soapy water solution. DO NOT test for gas leaks
using a match or open flame.
b. Brush the soapy water solution on all gas pipes, joints
and fittings.
c. Check for bubbling soap. This means you have a leak.
Turn “OFF” gas and make the necessary repairs.
d. Recheck for leaks.
e. Rinse off soapy solution and wipe dry.
2. Is the new temperature-pressure relief valve properly
installed and piped to an adequate drain? See “Temperature-
Pressure Relief Valve” section.
3. Are the cold and hot water lines connected to the water
heater correctly? See “Water Piping” instructions in the
“Installing the New Water Heater” section.
Installing the New Water Heater (cont’d)
MODEL RATING PLATE
4. Is the water heater completely filled with water? See “Filling
the Water Heater” instructions in the “Installing the New
Water Heater” section.
5. Will a water leak damage anything? See the “Locating the
New Water Heater” section.
6. Is there proper clearance between the water heater and any-
thing that might catch fire? See the “Locating the New Water
Heater” section.
7. Do you have adequate ventilation so that the water heater
will operate properly? See “Combustion Air and Ventilation”
in the “Locating the New Water Heater” section.
8. Is the vent piping properly secured? See “Venting” instruc-
tions in the “Installing the New Water Heater” section.
9. Is there proper clearance between the vent pipe and any-
thing that might catch fire? See “Venting” instructions in the
“Installing the New Water Heater” section.
10. Is the vent pipe properly sloped and does the vent terminate
outdoors? See “Venting” instructions in the “Installing the
New Water Heater” section.
11. Do you need to call your gas company to check the gas pipe
and its hookup?
COLD WATER INLET
HOT
WATER
OUTLET
TEMPERED
WATER
OUTLET
SHUTOFF
VALVE
TEE
DRIP LEG
(Sediment trap)
PIPE CAP
EXHAUST
VENT TO
OUTDOORS
GAS
SUPPLY
TEMPERATURE-
PRESSURE RELIEF
VALVE
DISCHARGE PIPE
(Do not cap or plug)
PROVIDE A 6
″″
AIR
GAP BETWEEN THE
END OF THE
DISCHARGE PIPE
AND DRAIN
INTAKE FOR
COMBUSTION
AIR
FLUE PRODUCTS
DISCHARGE PIPE
AIR INTAKE PIPE
Vacuum Relief
required by
some codes
(refer to local
codes)
SHUTOFF VALVE
SUITABLE FOR WATER (POTABLE)
HEATING AND SPACE HEATING
AUTOMATIC STORAGE WATER HEATER
FOR DIRECT VENT INSTALLATION
ELECTRICAL RATING: VOLTS 115/HZ60/AMPS 2