MAINTENANCE
6) Remove the burner by removing the screw
on the left side and then slide the burner to
the left and lift out.
7) Remove the right and left side deflectors by
removing the 2 screws on each deflector.
REMOVING VALVE
1) Shut off the gas supply.
2) Remove the louvers (and bay door if it has
been installed).
3) Open the flush door and remove the door.
4) Remove the logs and side brick panels, if
installed.
5) Remove the grate by lifting up and out.
8) Remove the base brick panels.
9) Disconnect the inlet gas line.
10)Remove the 10 Phillips head screws secur-
ing the valve tray assembly in place and
then lift the entire assembly out.
Slide the burner to the left and lift out.
Grate
Remove the screw on the left
side of the burner.
Right Side
Deflector
Left Side
Deflector
11)Disconnect the 2 TP wires and the 2 TH
wires from the valve.
12)Undo the pilot tube from the valve with a 7/
16" wrench.
13)Undo the quick drop out thermocouple nut
on the valve with a 9mm (metric) wrench.
14)Remove the Piezo igniter wire and push
button assembly.
Valve Tray
Assembly
Lift entire valve tray
assembly out.
15)Undo the "gas out" flare nut with a 13/16"
wrench.
16)
Undo the "gas out" flare fitting with an 11/
16" wrench.
17)Remove the 4 Phillips head screws from the
sides of the valve bracket and remove
valve.
Hint: If you are using black pipe, ensure
that there is a union by the valve,
otherwise removal will be almost
impossible.
Thermopile
Wire
Thermocouple
Wire
Pilot Nut