INSTALLING VALVE
12)Hook up the gas line and check for gas
leaks with a soap and water solution or a
gas leak detector. (Do not use open flame
for leak testing.)
13)Fire up the unit.
14)Check the manifold pressure.
15)Reinstall the vermiculite, embers, rock-
wool and logs as needed.
16)Install and close the door and replace the
louvers.
MAINTENANCE
1) Attach the valve bracket to the valve with
the 4 (m5x8 metric) screws provided.
2) Reconnect the "gas out" 90
o
elbow flare
fitting with an 11/16" wrench.
3) Reconnect the "gas out" flare nut with a
13/16" wrench.
4) Reconnect the quick drop out thermocouple
nut with a 9mm wrench.
5) Reconnect the pilot tube nut with a 7/16"
wrench.
6) Scrape off the old gasket from the floor of
the firebox.
7) Install a new gasket and reinstall the valve
assembly.
Note: Failure to install a new gasket may
severely affect the appliance per-
formance.
8) Reinstall the 12 hold down screws.
9) Hook up the 2 TP and 2 TH wires to the
appropriate connections on the valve.
10)Reinstall the burner grate. Put a dab of high
temperature silicone over the 3 screw holes.
11)Install Burner tube.