Regency P42-LP3 Indoor Fireplace User Manual


 
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 15
INSTALLATION
RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS
(Propane & Natural Gas)
Note: Must use optional rigid pipe adap-
tor when using rigid pipe vent
systems (Part # 510-994).
Note: Regency Direct Vent System (Flex)
is only approved for horizontal ter-
minations.
The shaded area in the diagram shows all allowable combinations of straight
vertical and offset to vertical terminations with rigid pipe vent systems for
Propane and Natural Gas.
Maximum two 45
o
elbows allowed.
Vent restrictor #6 must be used in shaded area in diagram
below.
Vent must be supported at offsets
The P42 is approved for a
37 ft. (11.3m) straight ver-
tical, including a 20" (0.5m)
horizontal offset using
two 90
o
elbow (two 45
o
elbows equal one 90
o
el-
bow) with rigid pipe vent
systems for Propane and
Natural Gas, as per the
diagram to the right.
Vent restrictor #6
is required for ter-
minations in shad-
ed area.
Vent must be sup-
ported at offsets
Diagram 1
Diagram 2