Regency P42-LP3 Indoor Fireplace User Manual


 
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace
30
4-7/16"
Openings for
electrical connections
Power IN
Millivolt Wires
5-1/2"
1-1/2"
WIRING DIAGRAM
CAUTION: Label all wires
prior to disconnection
when servicing controls.
Wiring errors can cause
improper and dangerous
operation.
No electrical power supply is required for the
gas control to operate. 120 Volt AC power is
needed for the fan switch and blower. The fan
can be hard wired if desired. A terminal block
is provided on the left hand side of the unit. A
three wire power cord can also be used and
plugged into a suitable receptacle.
(Do not cut the ground terminal off under
any circumstances.)
NOTE: Even if the fan is not purchased with the
unit, it is still a good idea to hardwire the terminal
block in case the fan is installed at a later date.
** However DO NOT leave this connection
live until the fan is installed.**
Caution: Ensure that the wires do
not touch any hot surfaces and
are away from sharp edges.
INSTALLATION
Thermodisc
Green
Green (Ground)
White (Neutral)
Black (Live)
Black
White
White
(*by others)
(*by others)
Black
Black
Ground for
mobile home
120 VAC
60HZ
(*by others)
Fan
Rotary Speed
Control
ON OFF
Fan
(*Supplied
by others
- install
according to
local code)
Lockwasher
Fan
ground
Power cord
ground wire
Star washer
Nut
Nut
#8 Ground Lug
(mobile home
approved)
Star washer
Piezo
Ignitor
To Thermocouple IN
Pilot
Assembly
H
I
L
O
O
F
F
O
N
P
I
L
O
T
Gas Pilot
Thermopile
Thermocouple
Electrode
Remote Transmitter
(Optional)
ON OFF
Regency
Remote Receiver
or Thermostat
(Millivolt) (Optional)
Brown
Red
Black
White
"S.I.T" Valve
To Burner
ON / OFF
Switch
(To THTP)
(To TH)
Gas
In