6 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
14)Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.)
be used in this appliance.
15)The appliance area must be kept clear and
free of combustible materials, (gases and
other flammable vapours and liquids).
INSTALLATION
CHECKLIST
1) Check Clearances to Combustibles (page
6), location of unit (page 6) and fluing
requirements (pages 6-9).
2) Install fluing: Check all fluing requirements,
pages 8-12.
3) Make gas connections, page 12. Test the
pilot. Must be as per diagram, pages 15 &
22.
4) If necessary, convert from NG to LPG (page
13).
5) Install log set, page 15.
6) Install Front Door Front, page 16.
7) Test Gas Pressure, page 17.
8) Install Louvres, page 17.
9) Install optional Remote Control, page 18.
10)Final check, page 18.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to
customer.
This includes:
1) Clocking the appliance to ensure the cor-
rect firing rate (rate noted on label) after
burning appliance for 15 minutes.
2) If required, adjusting the primary air to
ensure that the flame does not carbon. First
allow the unit to burn for 15-20 min. to
stabilize.
CAUTION: Any alteration to the product
that causes sooting or carboning that
results in damage is not the responsibil-
ity of the manufacturer.
LOCATING YOUR
REGENCY GAS STOVE
When selecting a location for your stove, en-
sure that the clearances listed above are met as
well as ensuring that there is adequate acces-
sibility for servicing and proper operation.
For Flu Termination requirements, see page 7.
This appliance is Listed for bedroom installa-
tions when used with a Listed Millivolt Thermo-
stat. Some areas may have further require-
ments, check local codes before installation.
This appliance is Listed for Alcove installations,
maintain minimum Alcove clearances as fol-
lows, minimum ceiling height of 1.7m, minimum
width of 1.0m and a maximum depth of 0.9m.
INSTALLATION
Use the minimum clearances shown in the
diagrams below:
FG37-NG & FG37-LPG Clearances
A Side Wall to Unit 190 mm
B Back Wall to Unit 76 mm
E Side Wall to Unit 114 mm
FG37-NG & FG37-LPG
Reference Dimensions
C Floor to Flue Centerline 635 mm
D Side Wall to Flue Centerline521 mm
A) Cross Corner
B) Flush with Wall/Alcove
C) Flat on Wall Corner
D) Flat on Wall
CLEARANCES TO
COMBUSTIBLES
The clearances listed are MINIMUM distances.
Measure the clearance to both the appliance
and the chimney connector. The farthest
distance is correct if the two clearances
do not coincide. For example, if the appliance
is set as indicated in one of the diagrams but the
connector is too close, move the stove until the
correct clearance to the connector is obtained.
This appliance may be installed only with the
clearances as shown in the situations pictured.
Do not combine clearances from one type
of installation with another in order to
achieve closer clearances.
This unit can be installed on a solid combustible
surface like a wood floor. This unit can also be
installed directly on carpeting or vinyl when the
bottom pedestal cover plate (provided with unit)
is installed.
COMBUSTION AND
VENTILATION AIR
The combustion air from this appliance is drawn
from outside the building through the outer flue.
Extra provision for combustion air inside
the room is not required.
Minimum ceiling height
is 914 mm from top of
unit.