18 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1) Clocking the appliance to ensure the cor-
rect firing rate (rate noted on label) at 15
minutes.
2) If required, adjusting the primary air to
ensure that the flame does not carbon. First
allow the unit to burn for 15 min. to stabilize.
CAUTION
Any alteration to the product that causes
sooting or carboning that results in dam-
age to the exterior facia is not the respon-
sibility of the manufacturer.
INSTALLATION
WIRING
CAUTION: Label all wires prior to
disconnection when servicing con-
trols. Wiring errors can cause im-
proper and dangerous operation.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
This heater does not require a 240V A.C. supply
for the gas control to operate. A 240V A.C.
power supply is needed for the fan/blower
operation.
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
OPTIONAL
REMOTE CONTROL
Use the Regency Remote Control Kit approved for
this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter and a wall mounting plate.
1) Choose a convenient location to mount the
hand held transmitter, protection from extreme
heat is very important.
The remote can also be used as a wall thermostat.