Regency FG37-LPG Stove User Manual


 
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 25
MAINTENANCE
4) Remove the two outside frame pieces by
removing two screws per side. See dia-
gram below.
REMOVING VALVE TRAY
If your valve requires maintenance or replace-
ment, follow these instructions:
NOTE: Always shut off the gas and dis-
connect the power supply before
removing the valve.
1) Open the front door and carefully remove
the logs and lava rock.
2) Remove the burner by removing the two
1/4" hex head screws. See diagram below.
3) Open the front pedestal door and unhook
chain. You may want to put a soft cloth on
the base of the unit so that when the
pedestal door is open it doesn't scratch the
paint. See diagram below.
5) Remove the front plate by undoing the 6
screws.
6) Disconnect the manual switch cable and
reset cables.
7) Disconnect the gas pipe line at the valve.
8) Remove the pedestal back cover by remov-
ing the 4 Philips screws.
9) Disconnect the 5 pin molex connector.
10)Disconnect the ground wires.
11)Remove the 20 x 1/4" hex head screws
holding the burner tray assembly in place.
12)Carefully lift the burner tray assembly out.
13)To replace the burner tray assembly,
reverse these instructions.
Reset Cables
Ground
Wire
5 Pin
Molex Connector
Manual Switch
Cable