Regency E21 Indoor Fireplace User Manual


 
9
U20/E21 Gas Insert Zero Clearance Kit
INSTALLATION
OPTIONAL OUTSIDE COMBUSTION AIR SUPPLY INSTALLATION
A 4" (100 mm) dia. aluminum flex pipe or equivalent may
be installed from the outside (with a proper exterior
cover) to the Zero Clearance cabinet. There is an outside
hole provided on the rear wall of the kit. This will provide
adequate outside combustion air supply to the heater.
Specifications
Min. Inlet Input
Gas Pressure Rating
Natural Gas 4.5" w.c. 21,000 Btu/hr
1.12 kP 22 mj/h
Propane 11" w.c. 21,000 Btu/hr
2.74 kPa 22 mj/h
ELECTRICAL SUPPLY
Provide 120 VAC, 60 Hz (in Australia and New Zealand: 240 VAC,
50 Hz) receptacle within 24"(610mm) of the left side of the appliance
(not inside the Zero Clearance Cabinet). Plug the cord on the
appliance into the receptacle.
GAS SUPPLY LINE
An authorized service person should install the gas line in accordance with all local building codes. If codes permit,
flex gas line or coiled copper tubing may be used as gas supply line. The suggested way to install the gas supply
line is as follows: run 1/2" (9.5 mm) NPT gas line to the left side of the framed opening. (See U20/E21 installation
instructions for additional information).