Raypak 1334001 Water Heater User Manual


 
13
$ If louvers, grills or screens are used on the
o
penings, obtain the net free area from their suppli-
er or manufacturer. If the design free area of a louver
is not known nor available, it shall be assumed that
wood louvers will have 20-25 percent free area and
m
etal louvers will have 60-75 percent free area as
specified in the National Fuel Gas Code.
&.7=270
>=-88;7<=*55*=287<
8-.5
1. Remove the front (4) screws.
2. Line up outdoor top vent opening over heater vent
opening.
3. Lower outdoor top onto unit lining up slots in the
outdoor top with screws holes in jacket top.
4. Reinstall (5) screws to secure jacket top and out-
door top to unit.
Fig. 4: Outdoor Top Installation
8-.5<*7-
&.7= $.;627*5 >=-88; #=*,45.<< $89
7<=*55*=287
1. Insert tabs into keyhole (4 places).
2. Snap tabs into keyholes so as not to pull out.
Outdoor Top
8-3/8"
OUTDOOR
FLOOR BASE
Fig. 5: Outdoor Top Installation
Pagoda Top (Shipped Loose with Heater)
Fig. 6: Outdoor Top Installation