Raypak 0180B Type H Boiler User Manual


 
RECEIVING EQUIPMENT
On receipt of your equipment, visually check for exter-
nal damage to the carton. If the carton is damaged, it
is suggested that a note be made on the Bill of Lading
when signing for the equipment.
Remove the boiler from the carton, and if it is dam-
aged, report the damage to the carrier immediately. Be
sure that you receive the number of packages indicat-
ed on the Bill of Lading. Claims for shortages and
damages must be filed with carrier by consignee.
Purchased parts are subject to replacement only
under the manufacturer's warranty. Debits for defec-
tive replacement parts will not be accepted and
defective parts will be replaced in kind only per our
standard warranties.
When ordering parts, you must specify Model and
Serial Number of the boiler. When ordering under war-
ranty conditions, you must also specify date of
installation.
Raypak recommends that this manual be reviewed
thoroughly before installing the boiler. If there are
any questions which this manual does not answer,
please contact your local Raypak representative.
GENERAL
SPECIFICATIONS
Raytherm hydronic boilers are design certified and
tested under the requirements of the latest edition of
the American National Standard, ANSI Z21.13/CSA
4.9. Each boiler has been constructed and pressure
tested in accordance with the requirements of Section
IV of the American Society of Mechanical Engineers
Code, and factory fire tested.
These boilers are designed for indoor installation with
a built-in drafthood, and a built-in sub-base for com-
bustible flooring. Models are available with standing
pilot, or with an intermittent ignition device (IID).
These boilers are equipped with the following compo-
nents: water circulation pump, pressure relief valve,
temperature/pressure gauge, adjustable high limit
switch, drain valve, fast response temperature sensor,
40 VA transformer, pump relay, vent thermal switch,
flame roll-out switch, and redundant combination gas
valve. Two-stage gas valve (50% firing on first stage)
is standard on models H-0090, H-0135 and H-0180.
The automatic ignition models and some standing pilot
models are provided with a plug-in connector that is
compatible with the Honeywell D80D vent damper.
Similar type vent dampers made by other manufactur-
ers, and design certified by a nationally-recognized
testing agency, under the ANSI Z21.66 standard, may
also be used.
Follow the installation instructions furnished with the
vent damper package. The plug-in connector can also
be used with power venters. Refer to the specific
installation instructions supplied by the power vent
manufacturer.
5