Quadra-Fire MTVERNON-AE-PMH Stove User Manual


 
R
September 1, 2008
7034-106E
Page 21
Mt. Vernon Pellet Stove (AE)
1. When mounting the wall control thermostat on the wall,
be sure to follow your thermostat wall control’s instal-
lation instructions carefully.
NOTE: The wall control thermostat should be
mounted on an inside wall and not in direct line
with the appliance convection air.
NOTE: If the wall control thermostat is located too
close to the appliance, you may need to set the
temperature setting slightly higher to maintain the
desired temperature in your home.
2. There is a 5 screw terminal block located on the back
lower left corner of the appliance directly above the
power cord inlet.
The center 3 screws are for the wall control thermostat
wires and the 2 outer screws are mounting screw and
should not have wires attached to them.
The thermostat wires are color coded. The green wire
is on the left, the white in the middle and the red on the
right.
F. Wall Control Thermostat Installation
Figure 21.2
Shock hazard.
Do NOT remove grounding prong from plug.
Plug directly into properly grounded 3 prong
receptacle.
Route cord away from appliance.
Do NOT route cord under or in front of appliance.
CAUTION
volt Po er nlet for
optional atter a k p
o shold Po er
Cord nlet
all Control hermostat ires
Atta h to Center S re s
reen hite Red
Red Wire
Top
Bottom
White Wire
Green Wire
Figure 21.1 - Back Side of Wall Control with
Cover Off