Quadra-Fire CB1200I Indoor Fireplace User Manual


 
R
R
R
February 3, 2010
7014-188B
Page 37
CB1200-I Pellet Insert
Ash Build Up in Firebox
Pellets Back Up
In Feed Tube
Firepot Overfills
Tall, Lazy Flame, Orange in Color
Incorrect
Correct Flame Size, Yellow/White in Color
Correct
Figure 37.1
Figure 37.2
Figure 37.3
Fire Risk.
WARNING
High ash fuels, or lack of maintenance, can
cause the firepot to overfill. Follow proper
shutdown procedure if ash buildup exceeds
half way point in firepot.
Failure to do so could result in smoking,
sooting and possible hopper fires.
D. High Ash Fuel Content Maintenance
Frequency: When the ash build-up exceeds more
than half way up the repot.
By: Homeowner
Poor quality pellet fuel, or lack of maintenance, can create
conditions that make the repot ll quickly with ashes and
clinkers.
This condition makes the appliance susceptible to overll-
ing the repot with pellets which may result in smoking,
sooting and possible hopper res. Figure 37.1 shows an
example where the repot overlls, pellets back up into the
feed tube and ash has accumulated in the rebox.
An inefcient and non-economical method of burning of
fuel caused by poor quality pellet fuel is shown in Figure
37.2.
The correct ame size when good quality, premium pellet
fuel is burned is shown in Figure 37.3.
If the ash buildup exceeds the half way point in the repot
IMMEDIATE ATTENTION AND CLEANING IS REQUIRED.