Quadra-Fire CB1200I Indoor Fireplace User Manual


 
Page 12
7014-188B
February 3, 2010
R
CB1200-I Pellet Insert
R
R
Mark area of
floor to cut
Starter hole
Keep sharp edge of
metal floor away from
power cord
The rebrick (refractory), glass doors, screen rails, screen
mesh and log grates can be removed from a factory-built
rebox in order to gain minimum insert opening require-
ments.
Any smoke shelves, shields and bafes may be removed
from a factory-built rebox if attached with mechanical fas-
teners.
The metal oor of the factory-built rebox may be removed
to facilitate the installation of the insert only when a 1 inch
(25mm) airspace is provided between the insert and the
oor of outer wrap.
If the oor is made of thin metal, we recommend using a
Quarda-Fire oor protector, Part 811-0730, which is avail-
able through your dealer.
Figure 12.1. Measure and mark the metal oor for cutting.
With a drill, make a starter hole in each corner.
Figure 12.2. Using a saws-all, cut out the oor.
Figure 12.3. Place the insert into the factory-built rebox.
Ensure that the power cord can not be damaged by the sharp
metal edge. You may need to cut out a notch to accommo-
date the cord.
I. Removing Metal Floor of Factory-Built
Firebox
The fireplace must not be altered, except for the
exceptions listed below. Do not removal the bricks and
mortar from the existing replace.
The following modications are premissible:
Removal of damper or locked in open position
Removal of smoke shelf or bafe
Removal of ember catches
Removel of re grate
Removal of view screen/curtain
Removal of doors
External trim pieces which do not affect the operation
of the replace may be removed providing they can be
stored on or within the replace for reassembly if the insert
is removed.
The permanent metal warning label provided must be
attached to the back of the replace, with screws or
nails, stating that the replace may have been altered to
accommodate the insert, and must be returned to original
condition for use as a conventional replace. Figure
12.4.
If the hearth extension is lower than the replace opening,
the portion of the insert extending onto the hearth must
be supported.
Manufacturer designed adjustable support kit can be
ordered from your dealer.
Final approval of this installation type is contingent upon
the authority having jurisdiction.
J. Altering the Factory-Built Fireplace
WARNING! Risk of Fire!
Follow venting manufacturer’s clearances and instructions
when installing venting system.
NOTICE: In Canada when using a factory-built chim-
ney it must be safety listed, Type UL103 HT (2100
o
F)
[1149
o
C] CLASS “A” or conforming to CAN/ULC-
S629M, STANDARD FOR 650
o
C FACTORY-BUILT
CHIMNEYS.
NOTE: Refer to chimney liner manufacturer for recom-
mendations on supporting the liner. Installation into
replaces without a permit will void the listing
250-2061
WARNING
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING
FIREPLACE.
250-2061
Figure 12.4