Page 36
7014-188B
February 3, 2010
R
CB1200-I Pellet Insert
R
R
15. Soot and Fly Ash: Formation & Need for Removal
in Exhaust Venting System.
• Frequency: Yearly or more frequently depending on
ash build-up.
• By: Qualied Service Technician/Homeowner
Be sure the appliance is allowed to cool, has been unplugged
and the exhaust blower is off.
The products of combustion will contain small particles of y
ash. The y ash will collect in the exhaust venting system
and restrict the ow of the ue gases.
At start-up if there is incomplete combustion, or if there is a
shutdown or incorrect operation of the appliance it will lead
to some soot formation. This will collect in the exhaust vent-
ing system.
The venting system may need to be cleaned at least once a
year or more often depending upon the quality of your fuel
or if there is a lot of horizontal pipe sections. Ash will build
up more quickly in the horizontal sections.
16. Preparing Firebox for Non-Burn Season
• Frequency: Yearly
• By: Homeowner
a.
Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b.
Remove all ash from the rebox and vacuum thoroughly.
c. Paint all exposed steel, including cast-iron.
•
Use the Touch-Up paint supplied with the appliance;
or,
• Purchase paint from your local dealer.
• Must use a high-temperature paint made speci-
cially for heating appliances.
13. Cleaning Exhaust Blower - Requires No Lubrication
• Frequency: Yearly or as needed
• By: Quality Service Technician/Homeowner
• Task:: Contact your local dealer.
14. Cleaning Convection Blower - Requires No
Lubrication
• Frequency: Yearly or as needed
• By: Qualied Service Technician
• Task: Contact your local dealer.
12. Door Gasket Inspection
• Frequency: Prior to heating season
• By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
b. To inspect the door rope (gasket), open the door and
see that the door rope extends approximately 1/8 inch
(3mm) to 3/16 inch (9.5mm) from the door rope chan-
nel.
c. It should show signs of compaction all the way around
the door where the rope contacts the face of the appli-
ance. Conrm there are no air leaks.