Page 50
7051-158B
December 6, 2011
R
EDGE 60 Pellet Fireplace
A. Glass Replacement
1. To remove the door:
a. Swing open the front.
b. Remove the door by lifting it off the hinge pins.
c. Lay on a fl at surface face down.
2.
Using a Phillips head screwdriver, remove 4 screws, 2
on the top and 2 on the bottom. Figure 49.1.
3. Remove metal bracket.
4. Remove the glass.
5.
Replace with new glass with gasket.
6. Re-attach metal bracket with 4 screws.
7. Re-install door over hinge pins and close front.
Remove 4 screws
Glass with Gasket
Metal Bracket
Figure 49.1
WARNING! Risk of Injury!
• Glass is 5mm thick high temperature heat-resistant ceramic
glass.
• DO NOT REPLACE with any other material.
• Alternate material may shatter and cause injury
B. Combustion (Exhaust) Blower
Replacement
1. Follow the proper shut down procedures as outlined on
page 14, Section 3.A
2. The combustion blower is mounted in the lower right
rear of the appliance. Figure 49.2.
3. Use an 11/32 nut driver to loosen all six nuts, but do
not remove. Rotate the blower and remove from the
housing. Figure 49.3.
4. Disconnect the wires.
5. You will also need to replace the gasket, see Parts List
for part number.
6. Install replacement blower in reverse order and re-con-
nect the wires.
11
Replacement Parts
Loosen all 6 nuts, but do NOT Remove
Figure 49.2
Combustion Blower
Combustion Blower Located
Right Lower Side of Fireplace
Figure 49.3