15. Turn off and unplug heater and
let cool before servicing. Only a
qualified service person should
service and repair heater.
16. Operating heater above elevations
of 4,500 feet could cause pilot
outage.
17. Do not operate heater if any log
is broken. Do not operate heater
if a log is chipped (dime-sized or
larger).
18. To prevent performance problems,
do not use fuel tank of less than
100 lbs. capacity.
LOCAL CODES
lnstall and use heater with care.
Follow all local codes. In the
absence of local codes, use the
latest edition of The National Fuel
Gas Code. ANSZ223.1, also known
as NFPA54*.
*Available from:
American National Standards
lnstitute, lnc.
1430 Broadway
New York. NY10018
National Fire Protection
Association, lnc.
Batterymarch Park
Quincy. MA 02269
This heater is designed for vent-
free operation. State and local codes
in some areas prohibit the use of
vent-free heaters.
UNPACKING
1. Remove top inner pack.
2. Tilt carton so that fireplace is upright.
3. Remove protective side packaging.
4. Slide fireplace out of carton.
5. Remove protective plastic wrap.
6. Remove two self-tapping screws
on the screw , then lift and
pulling forward.
7. Remove log set by cutting plastic
ties.
8. Carefully unwrap logs.
9. Check for any shipping damage. If
fireplace or logs are damaged,
promptly inform dealer where you
bought the fireplace from.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an
Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/
pilot is a required feature for vent-
free room heaters. The ODS/pilot
shuts off the heater if there is not
enough fresh air.
PRODUCT IDENTIFICATION
Figure1-Compact Vent-Free Fireplace
Water vapor is a by-product of gas combustion.An unvented room
heater productes approximately one (1) ounce (30ml) of wter for
every 1,000 BTU’s (.3KW’s) of gas input per hour.
Unvented room heaters are recommended as supplemental heat
(a room) rather than a primary heat source (an entire house) .In
most supplemental heat application, the water vapor does not
create a problem. In most applications, the water vapor enhances
the low humidity atmosphere experience during cold weather.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
The following steps will help insure that water vapor does not
become a problem.
1. Be sure the heater is sized properly for the application,
including ample combustion air and circulation air.
2. If high humidity is experienced, a dehumidifier may be used
to help lower the water vapor content of the air.
3. Do not use an unvented room heater as the primary heat
source.
Remote control SYSTEM
This fireplace has a remote transimit-
ter.This system requires three
batteries, and provides electric
power outlet to operate.
Mantel
Decorative
Frame
Stove Cabinet
Screen
Log
Heater control
(Inside door)