Procom EL250RYLB-O Indoor Fireplace User Manual


 
10
WARNING: Failure to position
the parts in accordance with these
diagrams may result in property
damage or personal injury.
CAUTION: After installation and
periodically thereafter, check to en-
sure that no flame comes in
contact with any log. With the heater
set to HIGH, check to see if flames
contact any log. If so, reposition logs
according to the log installation
instructions in this manual. Flames
contacting logs will create soot.
INSTALLING LOGS
Figure 10 -Installing Log Set (Top
View)
INSTALLATION
Continued
IMPORTANT: Make sure log does not
cover any burner ports (see Figure10).
OPERATING HEATER
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: If you do not
follow these instructions exactly, a fire
or explosion may result causing prop-
erty damage, personal injury or
loss of life.
A. This appliance has a pilot which
must be lighted by control system,
When lighting the pilot, follow
these instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for
gas. Be sure to smell next to the
floor because some gas is
heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
SEE WARNING in Page 1 for proper
instructions.
C. Use only your hand to push in control
knob. Never use tools. If the the appli-
ance could not operate , don't try to re
pair it, Call a qualified service technician
or gas supplier.Forced or attempted re-
pair may result in a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and any
gas control which has been under
water.
TO TURN OFF GAS TO APPLIANCE
Shut off heater
1. Press the IGN/OFF button.(see fig 12)
2. Set the Switch on OFF location.(see fig 11)
Shutting off burner only( pilot stay lit)
1.Press the BURNER to set flame OFF se-
lect
Fig 12-Front of the Transmitter
NOTICE: During initial operation of
new
fireplace, burning logs will give off
a paper-burning smell. Orange flame
will also be present. Open a window to
vent smell. This will only last a few
hours.
CAUTION: Do not try to adjust heat-
ing levels by using the
equipment shutoff valve.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information,
page 3.
2. Make sure equipment shutoff
valve is fully open.
Figure 11 -Emergency Button and
ON/OFF Switch Location
If your remote transimitter is lost or mis-
placed , you can press the emergency
button to operate heater manually on or
off (see fig 11)