Potterton Solar - Solar Thermal Domestic Hot Water System 11
3.1.4 Overview:Construction of menu structure
The overview shows the whole menu structure.
A
ccording to basic adjustment and system type some
menu points may not be displayed.
Info Program Manual operation Basic setting
Current collector temperature Maximum temperature Pump1 off / on Collector protection function
/ Collector1 storage cylinder1 off / on
Minimum collector temperature Storage cylinder1 Pump2 / Valve1 Collector protection
/ Collector1 Td max (Td on) off / on temperature
Maximum collector temperature Storage cylinder1 Heating / Cooling / Temperature Re-cooling
/ Collector1 Td min (Td off) differential controller off / on
off / on
Current storage cylinder Maximum temperature of Re-cooling
temperature / storage1 at bottom storage cylinder2 temperature
Minimum storage cylinder Storage cylinder2 Tube collector
temperature / storage1 at bottom Td max (Td on) off / on
Maximum storage cylinder Storage cylinder2 Yield estimation
temperature / storage1 at bottom Td min (Td off) off / on
Current storage cylinder temp / Minimum Glycol type
storage2 at bottom / collector 2 pump rotating speed in %
Minimum storage cylinder temp / Start temperature Glycol percentage
storage2 at bottom / collector 2 Heating / cooling
Maximum storage cylinder temp / Hysteresis temperature Volume flow
storage2 at bottom / collector 2 heating / cooling Td
Current collector Temperature differential Controlling time in
temperature - return line controller: seconds
Maximum temperature of the
heating target Tmax
Current temperature Temperature differential Storage cylinder priority
heating / cooling / controller:
differential controller Minimum temperature of the
heating source heating source Tmin
Current temperature Temperature differential Frost protection
frost protection sensor / controller: off / on
differential controller heating Hysteresis Tdmax
target / universal measuring
point T6
Operating hours pump1 Temperature differential Frost protection sensor
controller: assignment
Hysteresis Tdmin
Yield storage1 Timeframe start 1,2,3 for the Frost protection:
independent controller, 4 for the start temperature
tube collector function
Operating hours pump2 Timeframe stop 1,2,3 for the Independent controller
independent controller, 4 for the assignment: Cooling, heating,
tube collector function temperature differential
controller
Yield storage2 Set time Sensor assignment for the
independent controller
Select basic configuration
3
.0 Commissioning of solar controller