Baxi Potterton 24/1.0 Boiler User Manual


 
12.0 Care of the Boiler
20
© Baxi Heating UK Ltd 2010
12.1 Cleaning the Outer case
The painted panels should be wiped with a damp cloth and
then dried completely. DO NOT USE ABRASIVE
CLEANING AGENTS.
12.2 Maintenance
The appliance MUST be serviced annually by a Baxi authorised
engineer.
12.3 Condensate drain
The condensate drain, located at the bottom of the appliance,
must not be modified or blocked. Blockage will cause the
appliance to shut down.
12.4 Protection & Precaution
1. The appliance incorporates frost protection for itself only,
fitted as standard. If the system has a Programmable Room
Unit mounted in a cradle on a wall then the central heating
system will also be protected.
2. In cold weather, if you are going away, turn the appliance off
at the time switch ONLY. Leave the mains supply switched
ON.
3. If a system frost thermostat has been fitted (your installer
will be able to advise you), then to operate correctly and
protect your system, the gas and electricity must be left on and
the appliance set in the central heating mode.
4. The boiler incorporates an integral pump protection feature
which continually monitors the time since the pump last
operated. To prevent seizure, the pump will operate for
approximately 1 minute if it has not run in the last 24 hours.
12.5 Fault Indication
1. If a fault occurs on the boiler an error code may be shown
on the facia display.
12.6 In an Emergency
If a gas leak occurs or is suspected, the boiler can be
isolated at the inlet valves as follows;
1. Using a suitable open ended spanner, turn the square
nut on the gas tap through 90° (
1
/
4
turn) in a clockwise
direction to isolate the gas supply at the boiler.
2. Call your Installer or Service Engineer as soon as
possible.
Gas Service Cock
View from under appliance
Off Position
On Position
Test Nipple
If you smell gas
Do not operate light switches
Do not operate any electrical equipment
Do not use a telephone in the hazardous area
Extinguish any naked flame and do not smoke
Open windows and doors in the hazardous area
Turn off the gas supply at the meter
Warn any other occupants and vacate the premises
Telephone the National Gas Emergency Service on:-
0800 111 999
Faulty boiler
If it is known or suspected that a fault exists
on the boiler, it must not be used until the fault
has been corrected by a competent person.
Warning !