Baxi Potterton 24/1.0 Boiler User Manual


 
11.0 Error Codes
19
© Baxi Heating UK Ltd 2010
Error code: Display Description Lockout/reset action
Eng Sup
280 : Engine dome overtemp Engine dome overtemp has operated AR
282: G83/ENS/G1M G83/ENS module has detected an unhealthy mains condition AR
285: Alternator Short Power monitor IC has detected a short-circuit condition AR
287: Eng head under temp Engine head temperature thermocouple measurement below
103 degrees C when the CX relay is energised AR
298: False flame engine Ionisation probe of engine burner detected false flame AR
299: False flame supplementary Ionisation probe of supplementary burner detected false flame AR
300: Eng head under temp Engine head control temperature less than 150 degrees C when
CX relay is energised UR
301: Eng head over temp Engine head control temperature greater than 540 degrees C AR
302: Eng head thermocouple Magnitude of the difference between the engine head control
and limit thermocouples is greater than 100 degrees C UR
303: Control thermocouple Engine head control thermocouple failure UR
304: Limit thermocouple Engine head limit thermocouple failure UR
309: Power fail detection Power failure to fan detected 24v dc supply AR
310: Power monitor comm. No data received from the power meter IC in the last 10 seconds
or the power monitor failed to register with the EGC
microcontroller within 10 seconds of power up AR
311: EGC comm. failure Communication timeout or communication failure AR
421: Eng bu exc temp diff h’ex Engine burner excessive temperature difference across the
heat exchanger AR
422: BCU Eng bu inconsistent Transmitted state of the engine burner BCU isn’t consistent AR
423: BCU Supp bu inconsistent Transmitted state of the supplementary burner BCU isn’t consistent AR
424: Rep. loss of flame Eng bu Repeated loss of flame engine burner UR
425: Rep. loss of flame Supp bu repeated loss of flame supplementary burner UR
11.1 List of Error Codes (cont)
This is a shortened list of the error codes, which will be displayed on the Programmer or on the room unit. If more than one error is active, the one with the
higher priority or the one that appeared first will be displayed.
Error codes 157,274,261,262 and 300 can be reset by the user by pressing the user reset button for 2 seconds, turning the dial to alter the flashing NO to a YES
and then pressing the OK button. After a few seconds the error should clear enabling a restart of the appliance. Errors 261 and 262 may indicate a problem with
the gas supply.
Errors 157,164,274 and 300 may indicate a problem with the central heating water fill or pump. If the problem persists contact the installer with the error code.
Error 158 indicates a possible blockage in the condense drain.
Error codes 10 through to 99 (except 97) are linked to installation and commissioning of your system and as such you should contact your installer to complete
commissioning.
Error codes that are shown as automatic reset will disappear once the fault has cleared. The appliance will restart if there is a demand except in the case of
errors 263 and 264 when the appliance must be switched off and on again to enable a restart.
All other error codes indicate a fault condition, which will require the attention of a service engineer.
UR = User Reset, AR = Automatic Reset, ARP = Automatic Reset after Power Down