Installation and commissioning
12
3.02.02 With control unit P323 MS
Switch on the machine. ●
Call up the input mode. ●
Call up the service function. ●
By turning the balance wheel in the sewing direction, ascertain the number of incre- ●
ments per turn (this maximum value appears under "POS" in the display before the rea-
ding jumps back to "0".
Call up the input mode. ●
Call up parameter " ● 721".
721
127
Enter the calculated max. value. ●
Conclude the input. ●
Switch off the machine. ●