Adjustment
41
1.08 Adjusting the automatic presser foot lift -910/06
Requirement
When the automatic presser foot lift is operated, the clearance between the presser foot
and the needle plate must be 9 mm for a small needle bar stroke and 13 mm for a large
needle bar stroke.
Move magnet 1 (screw 2) according to the requirement.
Fig. 1 - 36
1
2
9 or 13 mm